WebJun 30, 2024 · The 5700A and 5720A Multifunction Calibrators are five-function calibrators designed to address the most demanding electrical calibration workload. They source direct and alternating voltage and … Web5520A Black and White Extended Specifications Fluke Corporation 1 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or twice the time the 5520A has been turned off. (For example, if the 5520A has been turned off for 5 minutes, the warm-up …
Fluke 5520a specs
Did you know?
Web5520A High Performance Multi-Product Calibrators Technical Specifications Voltage DC Range: 0 to ±1020V Best 1 Year Specification:±12 ppm of setting Current DC Range: 0 to ±20.5A Best 1 Year Specification:±100 ppm of setting Resistance Range: 0 to 1100 M Best 1 Year Specification:±28 ppm of setting Voltage AC Range: 1 mV to 1020V WebData Acquisition Software. Temperature Calibration. ITS-90 Temperature Standards. ITS-90 Fixed-point cells. Standard Platinum Resistance Thermometers. Maintenance Apparatus. Liquid Nitrogen Comparison Calibrator. Resistance Bridges. Standard Resistors.
WebFluke 5520A. The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or twice the time. the 5520A has … Webabove. The Fluke 5720A can address all points directly ex-cept for ±100 µA dc, ±10 mA, and ±100 mA dc. For those points, use a 10 kΩ resistor like the Fluke 742A-10k to charac-terize the ±100 µA dc point. In the same way, a 10Ω 742A-10 can be used to characterize the ±10 mA dc point and a 1Ω 742A-1 can be used to charac-terize the ± ...
WebOct 31, 2005 · Download fl5xxxmcal, a LabVIEW IEEE 488.2 (GPIB),Serial Plug and Play (project-style) instrument driver for a Multi-Product Calibrator,Multifunction Calibrator,Low Frequency Calibrator from fluke, model(s): 5500, 5502, 5520, 5522, 5700, 5720, 5730, 57, 5820. Find instrument drivers that are available for this instrument for use in LabVIEW, … WebIf you need increased performance, the Fluke 5520A Multi-Product Calibrator expands your workload coverage even further with improved accuracy in nearly all areas and with several additional features and functions. Features include: Lower output uncertainties to meet the requirements of 5 1⁄2 and 6 1⁄2 digit multimeters.
Web5520A/5500A Multi-Product Calibrators Extended Specifications Fluke Corporation 3 DC Voltage Specifications Absolute Uncertainty, tcal ±5°C ±(ppm of output + µV) Ranges Stability Resolution Maximum Burden Current1 24 Hours, ±1°C ±(ppm of output + µV) 90 Days 1 Year 5520A 0 to 3.299999V 9 + 2 11 + 2 2 + 1.5 1 µV 10 mA
Webby Fluke, the protection provided by the Calibrator may be impaired. The 5520A Multi-Function Calibrator (referred to throughout this manual as either "the 5520A Calibrator" … chipping sodbury food bankWebSpecifications: 5522A Multi-Product Calibrator: Features: Parameters: Function & Range : Direct Volts: 0 to ± 1020 V: Direct Current: 0 to 20.5 A: Alternating Volts: 1 mV to 1020 V … chipping sodbury jewellery shopWebBoth models offer options to fully calibrate oscilloscopes to 300 MHz or 600 MHz. The 5520A also offers an option to fully calibrate oscilloscopes to 1.1 GHz. Both the 5500A and the 5520A are built to Fluke’s high standards for rugged durability so you can use them easily on or off the bench. grapes and yogurt recipeWebGet the best deals on fluke 5520 when you shop the largest online selection at eBay.com. Free shipping on many items Browse your favorite brands affordable prices. chipping sodbury memory cafeWeb16 rows · 5500A and 5520A uncertainty specifications include stability, temperature coefficient, ... grapes and yogurtWebCalibration Source No Substitute Fluke Model 5500A, 5520A Digital Multimeter No Substitute HP 3458A, HP 34401A* Test Leads, low leakage, RG-58/U type ... * HP … grapesbcshWebFluke 789 Processmeter Quick ... measuring instruments fluke processmeter 789 quick reference manual. * hp 34401a may only be used in conjuction with fluke 5520a. Source ... xw warning to prevent possible electrical shock, fire, or personal injury, read the “789 safety. Web test equipment fluke processmeter 787 specifications. Processmeter ... grapes arc in microwave